Automatic Controller By Accumulated Time Of Engine Run (Auto Start/Stop)

Automatic Controller By Accumulated Time Of Engine Run (Auto Start/Stop)

最終更新

価格:

R.F.Q

Engine operating time is detected through the ignition plug line and is counted until it reaches its set time (interval hours). When the operating time reaches the set time, the system time is activated through the replay to start and stop the pump automatically. In the event of a fault, an alarm is emitted. Five different set time (1,2,4,10,20 and 40 hours) can be selected according to road condition, weather and the kind of grease to be used.

Share Product:

詳細

Specification

  • Model: AGT-505D
  • Supply Voltage: 12 VDC and 24 VDC (SHARED)
  • Start timer setting time: 1,2,4,10,20 and 40 hours (Switched by the DIP switch)
  • Alarm timer setting time: 6 minutes (Fixed)
  • Output: SK-505 motor: MAX. 3.0 A
  • Ambient Temperature: -20 degree + 60 degree
  • Ambient Humidity: 85% RH max.
  • Weight: (Free of dew condensation) 320gr
  • Product Code: RK844200