Model code | NC | NB | NA | |||
Application | Standard nuclear power applications at nuclear reactor facilities | Inside/Outside reactir containment at nuclear reactor facilites | Inside reactor containment | |||
Environmental conditions | General envinronmental conditions in operation | General environmental conditions in operation inside/outside reactor containment and in LOCA outside reactar containment | Environmental conditions in LOCA | |||
Usual | 40°C | Usual | 60°C | Usual | 60°C | |
Emergency | Emergency | 100°C | Emergency | 179 ~ 190°C | ||
Insulation class | Class H | Class H | Class H | |||
Nameplate material | Aluminium | Aluminium | Aluminium | |||
Coil/Housing finish | Electroless nickel plating | Electroless nickel plating | Electroless nickel plating | |||
Material- Elastomer | Nitriel rubber | Flurine rubber or ethylene propylene | Flurine rubber or ethylene propylene | |||
Material - Cartrige | Brass | Brass | Brass | |||
Material - Poppet | Resin | Stainless steel | Stainless steel | |||
Inspection criteria - insulation resistance | 100M or more | 100M or more | 100M or more | |||
Inspection criteria - Withstand voltage | AC2000V, 1minute | AC2000V, 1 minute | AC2000V, 1 minute | |||
Environmental test | none | NUPEC | IEEE382-1980 | |||
Outside reactor containment | LOCA test | Conform to IEEE 382-1980 | ||||
Serial No. | Individual number | Individual number | Individual number | |||
Inspection record | Record for each valve | Record for each valve | Record for each valve | |||
MIL sheet (main body) | none | Material test reports by raw material manufacturer | Material test reports by raw material manufacturer |
Spesifikasi
Jenama | |
Asal | JP |