GDS Gas Detector 15/30J-P1
价格:
征求报价
Share Product:
资料
Power Supply - 15 to 30vDC 24v nominal
Outputs - 3 wire - 4~20mA
4 wire - CAN bus
Relays (optional)
Low alarm S.P.C.O
High alarm S.P.C.O
Fault alarm S.P.C.O / overrange
Rating 0.5A @30vDC
Inhibit option during servicing
Logging - Addressable sensors only / Intervals - one minute to one hour / Storage - 2,880 readings
Temperature -15˚C to 55˚C
Humidity - 0˚C to 99% RH - non condensing
DETECTOR HEAD - Type – P 1 S afe area use
Ingress Protection - IP63, + U niversal fitting IP65
Material - ABS - black
Sensor Inserts - 4 series
Electrochemical
Infra Red
Semiconductor
Pellistor - Catalytic
PID
Accessories - Optional
Collector Cone + Universal Fitting
Universal Fitting (test gas applicator/spray deflector)
Flow Block
Duct Mount Kit
Detector Head Weather Shield
JUNCTION BOX
Type - 30J Safe area use only
Deep box (D) Shallow Box (S)
Ingress Protection - IP64
Material - ABS Flame retardent FR 40 / Lid Screws M4SS
Finish - Signal White RAL 9003
Weight - 380gms
Entries - Rear 5-20mm knock outs / Sides, Top, Bottom - not specified
Mounting
Standoffs - M4 or N o 8 screws
Drill at (C) when standoffs removed
Conduit box - drill at (A) 4.5mm
Surface mount box - drill at (B) 4.5mm
EU Design No. - 01359723-0001